·Integrated design, compact structure,fine and elegent
·IHigh quality,durable,friendly operation and simple maintenance
·IMenu-driven management system, expanding the use of space
·IWith O2 concentration continuously monitoring funtion
·I8 inch coloful TFT+high-luminance LCD Display
·Optional: a) Et CO2
Main Unit:
·Working mode: For the closed system, half-closed system and half-open system
·Application: Adult and Pediatric
·Low gas supply alarm: when O2 supply pressure is over low, the machine will arise >
(longer than) 7 seconds audible alarm.
·High pressure limitation: when airway pressure is higher than pre-set figure,the
machine will automatically start protection function. The airway pressure will stop
increasing (not increase any more) to keep patient safe.
·Low pressure protection: when O2 gas supply pressure is lower than 0.1MP.the
machine will automatically cut off N2O supply.
·When power supply fails, audible and visual alarms will arise.The machine will
continuously work by battery.
·O2 Flush: 25L/min~75L/min
·Gas Supply: O2: 0.28MPa~0.6MPa N2O: 0.28MPa~0.6MPa
·Power supply: AC 220V, 50 Hz Built-in UPS power supply for backup.
Flowmeter:
·O2/ N2O two tubes Flowmeter (0~1L/min 1~10L/min)
·Linkage of O2 and N2O, keep oxygen concentration over 25%
Anesthesia Ventilator:
·Pneumatically driven and electrically controlled
·Monitoring: Tidal volume, Frequency, MV, I/E ratio; Peak airway pressure,
O2 concentration, Apnea. Waveform (Pressure-time), Waveform (Flow-time)
·Working mode: Manual control or Automatic control
·Respiratory modes: IPPV, SIGH, SIMV/f/2, SIPPV, PEEP(0.5kPa ~ 2 kPa) Optional: EtCO2
·Tidal volume:0,50~ 1500mL
·Respiratory frequency:2~ 99bpm
·I:E:5:1 ~ 1:8 (adjustable)
·MV: not lower than 16L/min
·HFiO2: 21 ~ 100%
·High pressure limitation:2~ 6kPa
·Low pressure limitation:0~ 2kPa
Circle Absorber:
·New launching integrated CO2 Absorber, could be high temperature 134°C sterilized.
·Cup type Canister, around 2.5L, easily and fast change soda lime.
Anesthesia Vaporizer:
·High precise Anesthesia Vaporizer (Enflurane, Halothane, Isoflurane, Sevoflurane)
·Sevoflurane adjustment scope: 0~ 8% Vol;
Enflurane, Halothane, Isoflurane adjustment scope: 0~ 5%Vol
·Automatic compensation of flow, temperature and pressure
·Self-lock and interlock
·Volume:>250mL